//   NSN Parts  //  NSN 5925011083572

NSN 5925-01-108-3572 of Circuit Breaker - Product Details

Just NSN Parts, owned and operated by ASAP Semiconductor, is an industry-leading distributor of NSN 5925-01-108-3572 parts applicable in the aviation and defense industries. We aim to simplify the NSN 5925-01-108-3572 parts procurement process by enabling our customers to search through our inventory quickly and efficiently. Type in your desired NSN 5925-01-108-3572 part number such as AM4-Z5-2, APL1111-6584-1, IALHK1111-40745-1 into our search engine and, in a matter of seconds, available stock will appear.

We pride ourselves on our attention to detail and focus on quality control. We are FAA AC 0056B accredited and AS9120B, ISO 9001:2015 certified. We offer our customers a personalized and reliable service that will change your parts procurement process. If you would like to receive a quote today, fill out a request for quote form today.

Alternative NSN: 5925-01-108-3572
Item Name:Circuit Breaker
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5925 Circuit Breakers
NIIN: 011083572
NCB Code: USA (01)
Manufacturers: Eaton Corporation , Sensata Technologies Maryland Inc , Sensata Technologies Inc

Manufacturer's List for NSN 5925-01-108-3572, 5925011083572


Part Number Related To NSN 5925-01-108-3572, 5925011083572

Part No RFQ
AM4-Z5-2 RFQ
APL1111-6584-1 RFQ
IALHK1111-40745-1 RFQ

Characteristics Data of NSN 5925011083572

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAQBODY LENGTH2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
ADATBODY WIDTH2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
AKPXPOLE QUANTITY4
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY8 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE50.0 AMPERES AC FIRST LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE50.0 AMPERES AC SECOND LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE50.0 AMPERES AC THIRD LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS120.0 DC FOURTH LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC FIRST LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC SECOND LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC THIRD LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC FIRST LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC SECOND LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC THIRD LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT FIRST LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT SECOND LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT THIRD LOCATION
CPRHCIRCUIT PROTECTION TYPEUNDERVOLTAGE FOURTH LOCATION
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC FIRST LOCATION
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC SECOND LOCATION
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC THIRD LOCATION
CPRLTRIP RELEASE CHARACTERISTICINSTANTANEOUS FOURTH LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY FIRST LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY SECOND LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY THIRD LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 FIRST LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SECOND LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 THIRD LOCATION
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY4 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE,TWO,THREE,AND FOUR LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONRELAY TRIP FOURTH LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP FIRST LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SECOND LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP THIRD LOCATION
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT FIRST LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SECOND LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT THIRD LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
CTJSUNPACKAGED UNIT WEIGHT12.500 OUNCES NOMINAL
CWJKCASE MATERIALPLASTIC
FREQFREQUENCY IN HERTZ400.0 FIRST LOCATION
FREQFREQUENCY IN HERTZ400.0 SECOND LOCATION
FREQFREQUENCY IN HERTZ400.0 THIRD LOCATION
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY10 THREADED STUD

Get More Relevant NSN for NSN 5925-01-108-3572, 5925011083572

SEND INSTANT RFQ

Guaranteed quotes back within 15 minutes, 24/7 x 365

Spotlight Banner Contact Banner