NSN 5925-01-145-7746 of Circuit Breaker - Product Details
Just NSN Parts, owned and operated by ASAP Semiconductor, is an industry-leading distributor of NSN 5925-01-145-7746 parts applicable in the aviation and defense industries. We aim to simplify the NSN 5925-01-145-7746 parts procurement process by enabling our customers to search through our inventory quickly and efficiently. Type in your desired NSN 5925-01-145-7746 part number such as ETN-1006 into our search engine and, in a matter of seconds, available stock will appear.
We pride ourselves on our attention to detail and focus on quality control. We are FAA AC 0056B accredited and AS9120B, ISO 9001:2015 certified. We offer our customers a personalized and reliable service that will change your parts procurement process. If you would like to receive a quote today, fill out a request for quote form today.
Alternative NSN: 5925-01-145-7746 |
Item Name:Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 011457746 |
NCB Code: USA (01) |
Manufacturers: Spd Electrical Systems Inc |
Manufacturer's List for NSN 5925-01-145-7746, 5925011457746
Part Number Related To NSN 5925-01-145-7746, 5925011457746
Characteristics Data of NSN 5925011457746
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 5.875 INCHES NOMINAL |
ADAT | BODY WIDTH | 3.344 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.125 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.228 INCHES NOMINAL |
AKPX | POLE QUANTITY | 3 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 35.0 AMPERES AC AND 35.0 AMPERES DC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 500.0 AC AND 250.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC AND 2500.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS AND TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 10.000 MINIMUM AT 200 PCT AND 200.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CRTL | CRITICALITY CODE JUSTIFICATION | ZZZY |
CWJK | CASE MATERIAL | PLASTIC |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 PIN |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | MATERIAL WILL BE IN ACCORDANCE WITH SHIPS PARTS CONTROL CENTER ACTIVITY HX QUALITY CONTROL,MANUFACTURING AND TESTING SPECIFICATIONS |