When you would like to secure affordable procurement options for Te Connectivity Networks Inc part number 14946-5, do not hesitate to take advantage of the Request for Quote (RFQ) form on this page. As you complete this form, be sure to offer us important details like your target price and expected fulfillment timeframe, as well as information for contacting you with our response. Within 15 minutes of receiving and reviewing your submission, a member of our staff will reach out to you to present a tailored solution on Te Connectivity Networks Inc part number 14946-5 for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-00-451-8682 Item Description: Circuit Breaker | 5925 | 004518682 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 14946-5 | 2 | 9 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| CQXF | Inclosure Protection Type For Which Designed | VIBRATIONPROOF |
| AAQL | Body Style | SINGLE POLE TYPE |
| AKPX | Pole Quantity | 1 |
| PKWT | Unpackaged Unit Weight | 0.125 POUNDS |
| BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
| ABXD | Bushing Length | 0.250 INCHES NOMINAL |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 32.0 DC SINGLE LOCATION |
| AJWX | Mounting Surface To Terminal End Distance | 1.669 INCHES NOMINAL |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 DC SINGLE LOCATION |
| CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
| CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING |
| ADAT | Body Width | 0.656 INCHES NOMINAL |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 135.0 SINGLE LOCATION |
| CSSX | Switch Current Rating And Type In Amps | 7.0 DC |
| CPRQ | Reset Method | MANUAL |
| CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
| CPRX | Actuator Position Designation | AT POLE ONE |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| ADTV | Case Material | PLASTIC |
| CSWP | Switch Voltage Rating And Type In Volts | 28.0 DC |
| CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
| CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| CRTK | Switch Terminal Type | TAB, SOLDER LUG |
| THSD | Thread Series Designator | UNS |
| AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
| ADAQ | Body Length | 1.781 INCHES NOMINAL |
| CQJX | Nominal Thread Size | 0.469 INCHES |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.341 INCHES NOMINAL |
| TTQY | Terminal Type And Quantity | 2 SCREW |
| CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 12.0 AMPERES DC SINGLE LOCATION |
| MRC | Decoded Requirement | Clear Text Reply |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| AFJN | Fragility Factor | MODERATELY RUGGED |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT AND |
| CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| CMLP | Thread Quantity Per Inch | 32 |
| CPRW | Actuator Function | TRIP-RESET |
| CQXF | Inclosure Protection Type For Which Designed | SHOCKPROOF AND |
![]() |
AS9120B and ISO 9001:2015 |
![]() |