When you would like to secure affordable procurement options for Siemens Energy And Automation Inc part number HJD63B350, do not hesitate to take advantage of the Request for Quote (RFQ) form on this page. As you complete this form, be sure to offer us important details like your target price and expected fulfillment timeframe, as well as information for contacting you with our response. Within 15 minutes of receiving and reviewing your submission, a member of our staff will reach out to you to present a tailored solution on Siemens Energy And Automation Inc part number HJD63B350 for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-387-6502 Item PartTypeName: CIRCUIT BREAKER | 5925 | 013876502 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| HJD63B350 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| CPLM | Maximum Continuous Load Current Rating Per Pole | 350.0 AMPERES AC ALL LOCATIONS AND 350.0 AMPERES DC ALL LOCATIONS |
| AKPX | Pole Quantity | 3 |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 65000.0 AC ALL LOCATIONS AND 65000.0 DC ALL LOCATIONS |
| FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
| CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
| CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| CPRQ | Reset Method | MANUAL |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| AXHR | Mounting Facility Type And Quantity | 3 UNTHREADED HOLE AND 3 TERMINAL |
| ADAT | Body Width | 7.500 INCHES NOMINAL |
| CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| AJWX | Mounting Surface To Terminal End Distance | 4.000 INCHES NOMINAL |
| ADTV | Case Material | PLASTIC |
| ADAQ | Body Length | 11.000 INCHES NOMINAL |
| TTQY | Terminal Type And Quantity | 6 COMPRESSION |
| AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 600.0 AC ALL LOCATIONS AND 500.0 DC ALL LOCATIONS |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 138.0 ALL LOCATIONS |
| MRC | Decoded Requirement | Clear Text Reply |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
OVER 75000
Same-day
COMPLETE PURCHASING
FULLY CERTIFIED
COMPETITIVEBefore You Go, Take a Look at Our NSN Parts Catalog! Don’t forget That We Can offer A Competitive Quote Within 15 Minutes of Receiving Your RFQ form!
Request for Quote