When you would like to secure affordable procurement options for Sensata Technologies Maryland Inc part number IELBXK1-1-63-4.0, do not hesitate to take advantage of the Request for Quote (RFQ) form on this page. As you complete this form, be sure to offer us important details like your target price and expected fulfillment timeframe, as well as information for contacting you with our response. Within 15 minutes of receiving and reviewing your submission, a member of our staff will reach out to you to present a tailored solution on Sensata Technologies Maryland Inc part number IELBXK1-1-63-4.0 for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-596-7538 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015967538 | 0 | P | A | |
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | A | 0 | |||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| IELBXK1-1-63-4.0 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | Body Style | SINGLE POLE TYPE |
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 0.000 INCHES NOMINAL |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 4.0 AMPERES AC SINGLE LOCATION |
| FREQ | Frequency In Hertz | 50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 AC SINGLE LOCATION |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC SINGLE LOCATION |
| CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
| AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
| AKPX | Pole Quantity | 1 |
| CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| ADAT | Body Width | 0.750 INCHES MAXIMUM |
| TTQY | Terminal Type And Quantity | 2 SCREW |
| CPRQ | Reset Method | MANUAL |
| CXCY | Part Name Assigned By Controlling Agency | MAGNETIC CIRCUIT BREAKER, BX STYLE, ONE HANDLE PER UNIT, ROCKER, ACCIDENTAL-OFF PROTECTION, 1 POLE, SERIES, 50/60 HZ MOTOR START |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 1000.0 SINGLE LOCATION |
| FEAT | Special Features | BX STYLE HAS FLAT ROCKER ACTUATOR WITH ACCIDENTAL ACTUATION PROTECTION |
| CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
| AJEC | Boss Height | 0.439 INCHES NOMINAL |
| CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| AJWX | Mounting Surface To Terminal End Distance | 1.859 INCHES NOMINAL |
| ADTV | Case Material | PLASTIC |
| ADAQ | Body Length | 2.490 INCHES MAXIMUM |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.490 INCHES NOMINAL |
| CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 10.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 150.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| MRC | Decoded Requirement | Clear Text Reply |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
OVER 75000
Same-day
COMPLETE PURCHASING
FULLY CERTIFIED
COMPETITIVEBefore You Go, Take a Look at Our NSN Parts Catalog! Don’t forget That We Can offer A Competitive Quote Within 15 Minutes of Receiving Your RFQ form!
Request for Quote