When you would like to secure affordable procurement options for Sensata Technologies Maryland Inc part number IALN111-1REC4-23340-1, do not hesitate to take advantage of the Request for Quote (RFQ) form on this page. As you complete this form, be sure to offer us important details like your target price and expected fulfillment timeframe, as well as information for contacting you with our response. Within 15 minutes of receiving and reviewing your submission, a member of our staff will reach out to you to present a tailored solution on Sensata Technologies Maryland Inc part number IALN111-1REC4-23340-1 for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-394-8251 Item PartTypeName: CIRCUIT BREAKER | 5925 | 013948251 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| IALN111-1REC4-23340-1 | 5 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AKPX | Pole Quantity | 3 |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 10.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 150.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 40.0 AMPERES AC ALL LOCATIONS |
| ABXD | Bushing Length | 0.625 INCHES NOMINAL |
| AJWX | Mounting Surface To Terminal End Distance | 2.790 INCHES MAXIMUM |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC ALL LOCATIONS |
| FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
| CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| CQSM | Switch Location And Position Designation | INTERNAL AT POLE THREE |
| CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
| AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
| AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
| CSSX | Switch Current Rating And Type In Amps | 10.0 AC AND 3.0 DC |
| THSD | Thread Series Designator | UN |
| CPRQ | Reset Method | MANUAL |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| CPRW | Actuator Function | TRIP-RESET |
| ADAT | Body Width | 2.265 INCHES MAXIMUM |
| CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
| CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
| ADTV | Case Material | METAL |
| CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND 50.0 DC |
| CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| CQJX | Nominal Thread Size | 0.300 INCHES |
| ADAQ | Body Length | 2.265 INCHES MAXIMUM |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 2.094 INCHES NOMINAL |
| AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
| CRTK | Switch Terminal Type | SCREW |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
| TTQY | Terminal Type And Quantity | 6 SCREW |
| MRC | Decoded Requirement | Clear Text Reply |
| CPRX | Actuator Position Designation | AT POLE TWO |
| CMLP | Thread Quantity Per Inch | 32 |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
OVER 75000
Same-day
COMPLETE PURCHASING
FULLY CERTIFIED
COMPETITIVEBefore You Go, Take a Look at Our NSN Parts Catalog! Don’t forget That We Can offer A Competitive Quote Within 15 Minutes of Receiving Your RFQ form!