When you would like to secure affordable procurement options for Msi-Defence Systems Ltd part number 2440B0006, do not hesitate to take advantage of the Request for Quote (RFQ) form on this page. As you complete this form, be sure to offer us important details like your target price and expected fulfillment timeframe, as well as information for contacting you with our response. Within 15 minutes of receiving and reviewing your submission, a member of our staff will reach out to you to present a tailored solution on Msi-Defence Systems Ltd part number 2440B0006 for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5945-00-027-1359 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 000271359 | 0 | N | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| MS27222-2 | 3 | 2 | 2 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 3.734 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.865 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.687 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| ABKW | OVERALL HEIGHT | 2.941 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 3.305 INCHES MAXIMUM |
| ADTV | CASE MATERIAL | METAL |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 1 |
| APNA | WINDING DC RESISTANCE RATING | 51.0 OHMS NOMINAL SINGLE WINDING |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBME | CUBIC MEASURE | 36.245 CUBIC INCHES |
| CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE,SINGLE THROW,NORMALLY OPEN,DOUBLE MAKE,MOMENTARY ACTION |
| CRXH | TIME DELAY | 0.025 SECONDS MAXIMUM FIXED OPERATE TIME |
| CRXH | TIME DELAY | 0.05 SECONDS MAXIMUM FIXED RELEASE TIME |
| CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,DOUBLE BREAK,MOMENTARY ACTION AND 1 POLE,SINGLE THROW,NORMALLY OPEN,DOUBLE MAKE,MOMENTARY ACTION |
| CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES AC INDUCTIVE LOAD AND 50.0 AMPERES DC INDUCTIVE LOAD |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES AC MOTOR LOAD AND 50.0 AMPERES DC MOTOR LOAD |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES AC RESISTIVE LOAD AND 50.0 AMPERES DC RESISTIVE LOAD |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC MOTOR LOAD AND 1.0 AMPERES DC MOTOR LOAD |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC INDUCTIVE LOAD AND 5.0 AMPERES DC INDUCTIVE LOAD |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
| TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
| TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED STUD ALL FUNCTIONS |
| ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS27222 GOVERNMENT STANDARD |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
OVER 75000
Same-day
COMPLETE PURCHASING
FULLY CERTIFIED
COMPETITIVEBefore You Go, Take a Look at Our NSN Parts Catalog! Don’t forget That We Can offer A Competitive Quote Within 15 Minutes of Receiving Your RFQ form!
Request for Quote