310 12VDC by Humphrey Products Co - Receive a Competitive Quote
Part Number: 310 12VDC | Alternate P/N: 31012VDC | Manufacturer: Humphrey Products Co | NSN : 4810-01-562-1014 | Item Name : Valve Solenoid | CAGE Code: 24522 | FSC : 4810 Valves Powered | ||
We’re excited to announce that 310 12VDC NSN part is now available and ready for immediate shipping. Part number 310 12VDC is a Valve Solenoid manufactured by Humphrey Products Co with NSN 4810015621014. Are you interested in a quick and competitive quote for this part?
Just NSN Parts, owned and operated by ASAP Semiconductor, is a leading distributor of NSN (National Stock Number) parts, new and obsolete. Because of our dedication to quality, we’re the only independent distributor in the United States with a strict No China Sourcing Pledge. We’re also an AS9120B, ISO 9001:2015 certified, and FAA AC 0056B accredited member of the Aviation Suppliers Association (ASA). Our vast and comprehensive inventory of over 2 billion parts coupled with our shipping facilities in Washington, Oregon, California, New Maxico, Nevada, Arizona, Illinois, Minnesota, Pennsylvania, and New York, allow us to offer you some of the fastest delivery times in the industry.
If you’d like to learn more about NSN part number 310 12VDC Valve Solenoid, feel free to call us at our toll-free number, +1-714-705-4780, or email us at sales@justnsnparts.com. And, if you’d like to stay informed on new inventory or any promotions, feel free to download the ASAP Semiconductor App from Google Play or the App Store.
NSN Information for Part Number 310 12VDC with NSN 4810-01-562-1014, 4810015621014
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
4810-01-562-1014 Item PartTypeName: VALVE,SOLENOID | 4810 | 015621014 | N | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
310/12VDC | 5 | 2 | 3 |
Characteristics Data of NSN 4810-01-562-1014, 4810015621014
MRC | Criteria | Characteristic |
---|---|---|
AQLR | VALVE OPERATION METHOD | SOLENOID |
CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | 12.0 DC |
AECS | BOLT HOLE QUANTITY | 2 ALL ENDS |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG FAHRENHEIT 1ST RESPONSE 125.0 DEG FAHRENHEIT 2ND RESPONSE |
CWCK | NOMINAL THICKNESS | 0.750 INCHES ALL ENDS |
CWCQ | BOLT HOLE NOMINAL DIAMETER | 0.160 INCHES ALL ENDS |
CWCY | CENTER TO CENTER NOMINAL DISTANCE BETWEEN BOLT HOLES ALONG LENGTH | 0.660 INCHES ALL ENDS |
CWDC | CENTER TO CENTER NOMINAL DISTANCE BETWEEN BOLT HOLES ALONG WIDTH | 0.100 INCHES ALL ENDS |
AKGF | NOMINAL WIDTH | 1.250 INCHES ALL ENDS |
AKGG | NOMINAL LENGTH | 2.400 INCHES ALL ENDS |
MEDA | MEDIA FOR WHICH DESIGNED | AIR 1ST RESPONSE GAS, INERT 2ND RESPONSE |
AMPS | CURRENT RATING IN AMPS | 0.375 |
ADSK | FLOW CONTROL DEVICE NORMAL OPERATION POSITION | UNIVERSAL |
CQGM | MAXIMUM OPERATING PRESSURE | 125.0 POUNDS PER SQUARE INCH 1ST RESPONSE 8.5 BAR 2ND RESPONSE |