You have reached the Request for Quote (RFQ) page for part number X900219, an item sourced from General Dynamics Land Systems (CAGE Code 05257) that is classified with the item name Circuit Breaker. Here, you can utilize our online form to quickly secure tailored pricing and procurement options from our staff as the first step of procurement. With responses always being quick, be sure to get started as soon as possible if you would like to learn more about this part number.
Important Details for Part Number X900219
The part number X900219 is associated with General Dynamics Land Systems, identified by the CAGE Code 05257, and is typically referenced under the item name Circuit Breaker. It is categorized under the NSN 5925-00-985-7797, with the NIIN 009857797, INC 00136, and NCB code 00 (USA). Additionally, this part falls under the Federal Supply Group (FSG) 59 and Federal Supply Class (FSC) 5925 Circuit Breakers. For more information, these classifications provide further context about the component.
With the form provided, be sure to present our staff with key details on your needs, such as your target pricing, required quantity, and expected turnaround time. Once we receive and review your request for part X900219, a member of our staff will contact you in 15 minutes or less to present customized solutions for your comparisons. Once you make a purchase with us, you can expect our staff to work closely with you through each step of fulfillment to ensure that all needs are met with care and efficiency.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-985-7797 Item PartTypeName: CIRCUIT BREAKER | 5925 | 009857797 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
900219 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | POLE QUANTITY | 2 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED BUSHING |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.0 AMPERES AC AND 3.0 AMPERES DC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC AND 28.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500.0 AC AND 500.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 0.300 MINIMUM AND 1.500 MAXIMUM ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.150 MINIMUM AT 200 PCT AND 0.800 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED |
CWJK | CASE MATERIAL | PLASTIC |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNEF |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE HOOK |
![]() |