You have reached the Request for Quote (RFQ) page for part number LS-17228-2, an item sourced from Gems Sensors Inc (CAGE Code 04034) that is classified with the item name Switch Liquid Level. Here, you can utilize our online form to quickly secure tailored pricing and procurement options from our staff as the first step of procurement. With responses always being quick, be sure to get started as soon as possible if you would like to learn more about this part number.
Important Details for Part Number LS-17228-2
The part number LS-17228-2 is associated with Gems Sensors Inc, identified by the CAGE Code 04034, and is typically referenced under the item name Switch Liquid Level. It is categorized under the NSN 5930-00-758-5744, with the NIIN 007585744, INC 37187, and NCB code 00 (USA). Additionally, this part falls under the Federal Supply Group (FSG) 59 and Federal Supply Class (FSC) 5930 Switches. For more information, these classifications provide further context about the component.
With the form provided, be sure to present our staff with key details on your needs, such as your target pricing, required quantity, and expected turnaround time. Once we receive and review your request for part LS-17228-2, a member of our staff will contact you in 15 minutes or less to present customized solutions for your comparisons. Once you make a purchase with us, you can expect our staff to work closely with you through each step of fulfillment to ensure that all needs are met with care and efficiency.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-758-5744 Item PartTypeName: SWITCH,LIQUID LEVEL | 5930 | 007585744 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
LS17228 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 33.250 INCHES NOMINAL |
ACYN | AC VOLTAGE RATING | UNABLE TO DECODE220.0 VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
ACYR | DC VOLTAGE RATING | UNABLE TO DECODE6.0 VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | UNABLE TO DECODE60.0 HERTZ NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | UNABLE TO DECODE60.0 HERTZ NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
ADAV | OVERALL DIAMETER | 7.000 INCHES NOMINAL |
AFLW | ACTUATION METHOD | BUOYANCY |
APGW | CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.04 AMPERES RESISTIVE LOAD |
APGY | VOLTAGE RATING AT MAXIMUM RATED CURRENT | 110.0 VOLTS |
AWAE | FLOAT QUANTITY | 2 |
AWTN | OPERATING TEMP RATING | 65.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
BBJX | MOUNTING POSITION | VERTICAL |
BJKC | MAXIMUM CURRENT RATING | 0.08 AMPERES RESISTIVE LOAD |
BJKD | CONTACT ARRANGEMENT | SINGLE POLE,SINGLE THROW,NORMALLY OPEN |
BJKH | LIQUID TYPE FOR WHICH DESIGNED | FUEL,NONAIRCRAFT AND HYDRAULIC OIL AND LUBRICATING OIL AND SEA WATER |
ACYN | AC VOLTAGE RATING | UNABLE TO DECODE110.0 VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
ACYR | DC VOLTAGE RATING | UNABLE TO DECODE32.0 VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
AGBD | ELECTRICAL CONNECTION TYPE | CONNECTOR RECEPTACLE |
ALSF | INTERNAL BATTERY ACCOMMODATION | UNABLE TO DECODENOT INCLUDED 1ST ALTERNATE OPERATING POWER RQMT |
ALSF | INTERNAL BATTERY ACCOMMODATION | UNABLE TO DECODENOT INCLUDED 2ND ALTERNATE OPERATING POWER RQMT |
AXGY | MOUNTING METHOD | FLANGE |
BJKG | RELAY | NOT INCLUDED |
BJKP | MOUNTING DIMENSIONS | MTD BY FOUR 3/4 IN. HOLES EQUALLY SPACED ON A 5-1/2 IN. BOLT CIRCLE |
BJKQ | TANK INSERTION LENGTH | 31.000 INCHES NOMINAL |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Before You Go, Take a Look at Our NSN Parts Catalog! Don’t forget That We Can offer A Competitive Quote Within 15 Minutes of Receiving Your RFQ form!