You have reached the Request for Quote (RFQ) page for part number HDU36E, an item sourced from Engineered Air Systems Inc (CAGE Code 90598) that is classified with the item name Heater Duct Type Po. Here, you can utilize our online form to quickly secure tailored pricing and procurement options from our staff as the first step of procurement. With responses always being quick, be sure to get started as soon as possible if you would like to learn more about this part number.
Important Details for Part Number HDU36E
The part number HDU36E is associated with Engineered Air Systems Inc, identified by the CAGE Code 90598, and is typically referenced under the item name Heater Duct Type Po. It is categorized under the NSN 4520-00-182-7193, with the NIIN 001827193, INC 13028, and NCB code 00 (USA). Additionally, this part falls under the Federal Supply Group (FSG) 45 and Federal Supply Class (FSC) 4520 Space And Water Heating Equipment. For more information, these classifications provide further context about the component.
With the form provided, be sure to present our staff with key details on your needs, such as your target pricing, required quantity, and expected turnaround time. Once we receive and review your request for part HDU36E, a member of our staff will contact you in 15 minutes or less to present customized solutions for your comparisons. Once you make a purchase with us, you can expect our staff to work closely with you through each step of fulfillment to ensure that all needs are met with care and efficiency.
MRC | Criteria | Characteristic |
---|---|---|
ELEC | Voltage In Volts | 120 |
FUEL | Fuel Type | DIESEL FUEL OIL OR JP-4 JET FUEL |
NMBR | Quantity | 1 |
ABAY | Heat Discharge Outlet Type | STATIONARY |
ABBB | Speed Adjustments | SINGLE SPEED |
ABBE | Circulated Air Type | HEATED |
FAAZ | Phase | SINGLE |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
FREQ | Frequency In Hertz | 60 |
ABAM | Heat Medium Type | AIR |
BLJC | Ignition Method | ELECTRODE |
BDXJ | Heating Element Type | ELECTRIC NONIMMERSION |
MRC | Decoded Requirement | Clear Text Reply |
FTLD | Functional Description | A FORCED-AIR HEATER,DESIGNED FORUSE IN PORTABLE SHELTERS OF VARIOUS CONFIGURATIONS |
CRJT | Integral Fuel Tank Capacity | 26.4 GALLONS |
ACDC | Current Type | AC |
HGTH | Height | 32.000 INCHES NOMINAL |
AEJZ | Depth | 42.000 INCHES NOMINAL |
AAXX | Mounting Type | SKID |
ABBD | Maximum Air Flow Rate | 1400.0 CUBIC FEET PER MINUTE |
NTRD | Entry Date | 79-01-01 |
ABAZ | Heat Directing Device | FLEXIBLE DUCTS |
ABBA | Air Circulation Device | BLOWER WHEEL |
ALYC | Operating Control Type | ANY ACCEPTABLE |
ABGL | Width | 34.000 INCHES NOMINAL |
ABAW | Heat Outlet Quantity | 1 |
ABAX | Heat Delivery Direction | HORIZONTAL |
CSGC | Fuel Feed Method | INTERNAL PUMP |
CQXD | Heat Delivery Rate | 120000.0 BRITISH THERMAL UNIT |
![]() |