You have reached the Request for Quote (RFQ) page for part number BSP552, an item sourced from Edo Corp (CAGE Code 09017) that is classified with the item name Transformer Power. Here, you can utilize our online form to quickly secure tailored pricing and procurement options from our staff as the first step of procurement. With responses always being quick, be sure to get started as soon as possible if you would like to learn more about this part number.
The part number BSP552 is associated with Edo Corp, identified by the CAGE Code 09017, and is typically referenced under the item name Transformer Power. It is categorized under the NSN 5950-00-257-1615, with the NIIN 002571615, INC 32496, and NCB code 00 (USA). Additionally, this part falls under the Federal Supply Group (FSG) 59 and Federal Supply Class (FSC) 5950 Coils and Transformers. For more information, these classifications provide further context about the component.
With the form provided, be sure to present our staff with key details on your needs, such as your target pricing, required quantity, and expected turnaround time. Once we receive and review your request for part BSP552, a member of our staff will contact you in 15 minutes or less to present customized solutions for your comparisons. Once you make a purchase with us, you can expect our staff to work closely with you through each step of fulfillment to ensure that all needs are met with care and efficiency.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-00-257-1615 Item PartTypeName: TRANSFORMER,POWER | 5950 | 002571615 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 653266 | 6 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAJF | UNABLE TO DECODE | UNABLE TO DECODE |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.422 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.422 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.422 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.454 INCHES MAXIMUM SINGLE MO |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.422 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.422 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.422 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.454 INCHES MAXIMUM SINGLE MO |
| ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 2.203 INCHES MINIMUM AND 2.203 INCHES MINIMUM AND 2.203 INCHES MINIMUM AND 2.235 INCHES MAXIMUM2.235 INCHES MAXIMUM2.235 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 2.078 INCHES MINIMUM AND 2.078 INCHES MINIMUM AND 2.078 INCHES MINIMUM AND 2.110 INCHES MAXIMUM2.110 INCHES MAXIMUM2.110 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 2.734 INCHES MINIMUM AND 2.734 INCHES MINIMUM AND 2.734 INCHES MINIMUM AND 2.766 INCHES MAXIMUM2.766 INCHES MAXIMUM2.766 INCHES MAXIMUM |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALEDHERMETICALLY SEALEDHERMETICALLY SEALED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT3 SECONDARY SINGLE COMPONENT3 SECONDARY SINGLE COMPONENT |
| CBME | UNABLE TO DECODE | UNABLE TO DECODE |
| CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
| CQLC | UNABLE TO DECODE | UNABLE TO DECODE |
| CRBZ | WINDING OPERATING CURRENT | 104.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 114.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 209.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 110.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 110.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY55.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY55.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 110.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY55.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY55.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 55.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY110.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 9 TURRET |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
OVER 75000
Same-day
COMPLETE PURCHASING
FULLY CERTIFIED
COMPETITIVEBefore You Go, Take a Look at Our NSN Parts Catalog! Don’t forget That We Can offer A Competitive Quote Within 15 Minutes of Receiving Your RFQ form!
Request for Quote