AM4-A3A3A3A6-A-50-2 by Eaton Corporation - Receive a Competitive Quote
Part Number: AM4-A3A3A3A6-A-50-2 | Alternate P/N: AM4A3A3A3A6A502 | Manufacturer: Eaton Corporation | NSN : 5925-01-287-4283 | Item Name : Circuit Breaker | CAGE Code: 74193 | FSC : 5925 Circuit Breakers | ||
We’re excited to announce that AM4-A3A3A3A6-A-50-2 NSN part is now available and ready for immediate shipping. Part number AM4-A3A3A3A6-A-50-2 is a Circuit Breaker manufactured by Eaton Corporation with NSN 5925012874283. Are you interested in a quick and competitive quote for this part?
Just NSN Parts, owned and operated by ASAP Semiconductor, is a leading distributor of NSN (National Stock Number) parts, new and obsolete. Because of our dedication to quality, we’re the only independent distributor in the United States with a strict No China Sourcing Pledge. We’re also an AS9120B, ISO 9001:2015 certified, and FAA AC 0056B accredited member of the Aviation Suppliers Association (ASA). Our vast and comprehensive inventory of over 2 billion parts coupled with our shipping facilities in Washington, Oregon, California, New Maxico, Nevada, Arizona, Illinois, Minnesota, Pennsylvania, and New York, allow us to offer you some of the fastest delivery times in the industry.
If you’d like to learn more about NSN part number AM4-A3A3A3A6-A-50-2 Circuit Breaker, feel free to call us at our toll-free number, +1-714-705-4780, or email us at sales@justnsnparts.com. And, if you’d like to stay informed on new inventory or any promotions, feel free to download the ASAP Semiconductor App from Google Play or the App Store.
NSN Information for Part Number AM4-A3A3A3A6-A-50-2 with NSN 5925-01-287-4283, 5925012874283
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-287-4283 Item PartTypeName: CIRCUIT BREAKER | 5925 | 012874283 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
11426-90003 | 5 | 2 | 3 |
Characteristics Data of NSN 5925-01-287-4283, 5925012874283
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 2.468 INCHES MINIMUM AND 2.532 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.968 INCHES MINIMUM AND 3.032 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.906 INCHES MINIMUM AND 1.970 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.722 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.030 INCHES MINIMUM AND 2.094 INCHES MAXIMUM |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE,DOUBLE THROW |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.722 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
AJEC | BOSS HEIGHT | 0.140 INCHES MINIMUM AND 0.172 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.688 INCHES MINIMUM AND 2.752 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 4 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 8 THREADED HOLE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC FIRST LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC SECOND LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC THIRD LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SECOND LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC THIRD LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC FIRST LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SECOND LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC THIRD LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT FIRST LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SECOND LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT THIRD LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC FIRST LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SECOND LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC THIRD LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY FIRST LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SECOND LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY THIRD LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 FIRST LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SECOND LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 THIRD LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 4 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE,TWO,THREE,AND FOUR LINKED |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIRST LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SECOND LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP THIRD LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | EXTERNAL AT POLE FOUR |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT FIRST LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SECOND LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT THIRD LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND HUMIDITY RESISTANT AND MOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
CRTK | SWITCH TERMINAL TYPE | THREADED STUD |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 50.0 AC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC |
CTJS | UNPACKAGED UNIT WEIGHT | 9.500 OUNCES NOMINAL |
CWJK | CASE MATERIAL | PLASTIC |
FEAT | SPECIAL FEATURES | FOURTH POLE IS SWITCH ONLY |
FREQ | FREQUENCY IN HERTZ | 50.0 OR 60.0 FOURTH LOCATION |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST LOCATION |
FREQ | FREQUENCY IN HERTZ | 60.0 SECOND LOCATION |
FREQ | FREQUENCY IN HERTZ | 60.0 THIRD LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 THREADED STUD |