When you would like to secure affordable procurement options for Challenger Electrical Equipment Corp part number NB125, do not hesitate to take advantage of the Request for Quote (RFQ) form on this page. As you complete this form, be sure to offer us important details like your target price and expected fulfillment timeframe, as well as information for contacting you with our response. Within 15 minutes of receiving and reviewing your submission, a member of our staff will reach out to you to present a tailored solution on Challenger Electrical Equipment Corp part number NB125 for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-017-0018 Item PartTypeName: CIRCUIT BREAKER | 5925 | 010170018 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| NB125 | 5 | 9 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| ADAQ | BODY LENGTH | 3.344 INCHES NOMINAL |
| ADAT | BODY WIDTH | 2.000 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 2.312 INCHES NOMINAL |
| ADTV | UNABLE TO DECODE | UNABLE TO DECODE |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.000 INCHES NOMINAL |
| AJEC | BOSS HEIGHT | 0.219 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 2 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 TERMINAL |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 125.0 AMPERES AC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 10000.0 AC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS AND TIME DELAY ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 11.000 MINIMUM AT 200 PCT AND 29.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| CTJS | UNPACKAGED UNIT WEIGHT | 12.500 OUNCES NOMINAL |
| CWJK | CASE MATERIAL | PLASTIC |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 CLIP AND 2 COMPRESSION |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
OVER 75000
Same-day
COMPLETE PURCHASING
FULLY CERTIFIED
COMPETITIVEBefore You Go, Take a Look at Our NSN Parts Catalog! Don’t forget That We Can offer A Competitive Quote Within 15 Minutes of Receiving Your RFQ form!
Request for Quote