NSN 6685-00-514-3976 of Thermostat Flow Con - Product Details
Just NSN Parts, owned and operated by ASAP Semiconductor, is an industry-leading distributor of NSN 6685-00-514-3976 parts applicable in the aviation and defense industries. We aim to simplify the NSN 6685-00-514-3976 parts procurement process by enabling our customers to search through our inventory quickly and efficiently. Type in your desired NSN 6685-00-514-3976 part number such as 157D1-1305, 6569 into our search engine and, in a matter of seconds, available stock will appear.
We pride ourselves on our attention to detail and focus on quality control. We are FAA AC 0056B accredited and AS9120B, ISO 9001:2015 certified. We offer our customers a personalized and reliable service that will change your parts procurement process. If you would like to receive a quote today, fill out a request for quote form today.
Alternative NSN: 6685-00-514-3976 |
Item Name:Thermostat Flow Con |
FSG: 66 Instruments and Laboratory Equipment |
Federal Supply Class (FSC): 6685 Pressure Temperature And Humidity Measuring And Controlling Instruments |
NIIN: 005143976 |
NCB Code: USA (00) |
Manufacturers: Engineered Electric Company , Kurz And Root Generator Company Llc |
Manufacturer's List for NSN 6685-00-514-3976, 6685005143976
Part Number Related To NSN 6685-00-514-3976, 6685005143976
Part No | NSN | Item Name | QTY | RFQ |
---|---|---|---|---|
157D1-1305 | 6685-00-514-3976 | thermostat flow con | Avl | RFQ |
157D1-1305 | 6685-00-514-3976 | thermostat flow con | Avl | RFQ |
6569 | 6685-00-514-3976 | thermostat flow con | Avl | RFQ |
6569 | 6685-00-514-3976 | thermostat flow con | Avl | RFQ |
Characteristics Data of NSN 6685005143976
MRC | Criteria | Characteristic |
---|---|---|
AWTN | OPERATING TEMP RATING | 180.0 DEG FAHRENHEIT NOMINAL |
ADJH | MOUNTING METHOD | FLANGE |
AWTP | SPRING OPERATED PRESSURE RELIEF | NOT PROVIDED |
ADQU | FLOW CONTROL DEVICE | CHOKE |
AMSD | VALVE TRAVEL DISTANCE | 0.375 INCHES MINIMUM AND 0.400 INCHES MAXIMUM |
ALCD | USAGE DESIGN | DESIGNED FOR COOLING SYSTEM CONTROL |
ABKW | OVERALL HEIGHT | 4.642 INCHES MINIMUM AND 4.652 INCHES MAXIMUM |
AGWM | LARGEST OUTSIDE DIAMETER | 2.870 INCHES MINIMUM AND 2.878 INCHES MAXIMUM |
AWPA | THERMOSTAT TYPE | SOLID EXPANSION |
AWTM | OPENING TEMP RATING | 165.0 DEG FAHRENHEIT NOMINAL |