MRC | Criteria | Characteristic |
---|
AAQL | BODY STYLE | W/MTG TABS/FLANGES,TERMINAL S ON ONE SURFACEW/MTG TABS/FLANGES,TERMINAL S ON ONE SURFACEW/MTG TABS/FLANGES,TERMINAL S ON ONE SURFACEW/MTG TABS/FLANGES,TERMINAL S ON ONE SURFACEW/MTG TABS/FLANGES,TERMINAL S ON ONE SURFACE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ADAQ | BODY LENGTH | 4.000 INCHES NOMINAL4.000 INCHES NOMINAL4.000 INCHES NOMINAL4.000 INCHES NOMINAL4.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 4.562 INCHES NOMINAL4.562 INCHES NOMINAL4.562 INCHES NOMINAL4.562 INCHES NOMINAL4.562 INCHES NOMINAL |
ADAU | BODY HEIGHT | 4.625 INCHES NOMINAL4.625 INCHES NOMINAL4.625 INCHES NOMINAL4.625 INCHES NOMINAL4.625 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.164 INCHES NOMINAL0.164 INCHES NOMINAL0.164 INCHES NOMINAL0.164 INCHES NOMINAL0.164 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 5.125 INCHES NOMINAL5.125 INCHES NOMINAL5.125 INCHES NOMINAL5.125 INCHES NOMINAL5.125 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE S NO COMMON OR GROUNDED ELECTRODE S NO COMMON OR GROUNDED ELECTRODE S NO COMMON OR GROUNDED ELECTRODE S NO COMMON OR GROUNDED ELECTRODE S |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.250 INCHES NOMINAL2.250 INCHES NOMINAL2.250 INCHES NOMINAL2.250 INCHES NOMINAL2.250 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED MOUNTING HOLES2 UNTHREADED MOUNTING HOLES2 UNTHREADED MOUNTING HOLES2 UNTHREADED MOUNTING HOLES2 UNTHREADED MOUNTING HOLES |
BWGP | SECTION QUANTITY | 33333 |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASEHERMETICALLY SEALED CASEHERMETICALLY SEALED CASEHERMETICALLY SEALED CASEHERMETICALLY SEALED CASE |
CQBQ | CAPACITANCE VALUE PER SECTION | 10.000 MICROFARADS 2ND SECTION10.000 MICROFARADS 2ND SECTION |
CQBQ | CAPACITANCE VALUE PER SECTION | 20.000 MICROFARADS 3RD SECTION20.000 MICROFARADS 3RD SECTION |
CQBQ | CAPACITANCE VALUE PER SECTION | 5.000 MICROFARADS 1ST SECTION5.000 MICROFARADS 1ST SECTION AND 10.000 MICROFARADS 2ND SECTION AND 5.000 MICROFARADS 1ST SECTION20.000 MICROFARADS 3RD SECTION AND 10.000 MICROFARADS 2ND SECTION AND 5.000 MICROFARADS 1ST SECTION20.000 MICROFA |
CQJJ | NONDERATED OPERATING TEMP | 55.0 DEG CELSIUS MINIMUM AND-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM85.0 DEG CELSIUS MAXIMUM |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 120.0 AC-RMS 1ST SECTION AND 120.0 AC-RMS 1ST SECTION AND 120.0 AC-RMS 2ND SECTION AND 120.0 AC-RMS 2ND SECTION AND 120.0 AC-RMS 3RD SECTION120.0 AC-RMS 3RD SECTION |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 120.0 AC-RMS 1ST SECTION120.0 AC-RMS 1ST SECTION |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 120.0 AC-RMS 2ND SECTION120.0 AC-RMS 2ND SECTION |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 120.0 AC-RMS 3RD SECTION120.0 AC-RMS 3RD SECTION |
CRTP | TOLERANCE RANGE PER SECTION | 10.00 TO 10.00 PERCENT 1ST SECTION-10.00 TO 10.00 PERCENT 1ST SECTION |
CRTP | TOLERANCE RANGE PER SECTION | 10.00 TO 10.00 PERCENT 2ND SECTION AND-10.00 TO 10.00 PERCENT 1ST SECTION AND-10.00 TO 10.00 PERCENT 3RD SECTION AND-10.00 TO 10.00 PERCENT 2ND SECTION AND-10.00 TO 10.00 PERCENT 1ST SECTION-10.00 TO 10.00 PERCENT 3RD SECTION |
CRTP | TOLERANCE RANGE PER SECTION | 10.00 TO 10.00 PERCENT 2ND SECTION-10.00 TO 10.00 PERCENT 2ND SECTION |
CRTP | TOLERANCE RANGE PER SECTION | 10.00 TO 10.00 PERCENT 3RD SECTION-10.00 TO 10.00 PERCENT 3RD SECTION |
CWJK | CASE MATERIAL | METALMETAL |
TTQY | TERMINAL TYPE AND QUANTITY | 6 SOLDER STUD6 SOLDER STUD |